+86 18068001229 0102030405
Iindaba

I-MV Skid Compact, Izisombululo zamandla eziNjinerisiweyo zoBunjineli bokuHlaziywa kunye noKuqiniswa kweGridi
2025-08-29
I-MV Skid Compact imele eyona ncopho yezisombululo ezingabizi kakhulu kwiiprojekthi ze-Utility Scale Solar kunye ne-Energy Storage. Idibanisa ngaphandle komthungo ii-transformers ze-MV, ii-inverters, kunye nee-medium voltage switches kwiyunithi enye, inceda ngokukhawuleza nangokungenangxaki...
jonga iinkcukacha 
Ukucacisa Iingcamango ze-Electromagnetic kwimisebenzi yeTransformer
2025-08-28
Ukuchaneka kwesigama I-World Health Organisation (WHO) kunye ne-International Commission on Non-Ionizing Radiation Protection (ICNIRP) zahlula ngokungqongqo phakathi "kwe-electromagnetic fields" (ngaphantsi kwe-100 kHz) kunye "ne-electromagnetic radiation" (ngaphezulu kwe-100 k...
jonga iinkcukacha 
I-PT kunye ne-CT kwi-Transformers: IiNgwevu ezingadunyiswanga zeVoltage kunye ne-Current
2025-08-27
I-PT kunye ne-CT kwiiTransformers: IiNgcali Ezingadumiyo zeVoltage kunye neCurrent Xa kufikwa kwiitransformers, i-PT (i-Potential Transformer) kunye ne-CT (i-Current Transformer) zifana ne-duo enamandla yehlabathi lombane—uBatman noRobin. Basenokungathandi...
jonga iinkcukacha 
Indima ye-ELSP Current-Limiting Backup Fuse kwiTransformers
2025-08-26
Kwii-transformers, i-ELSP current-limiting backup fuse sisixhobo esibalulekileyo sokhuseleko esenzelwe ukukhusela i-transformer kunye nezixhobo ezinxulumene nayo kwiisekethe ezimfutshane ezinzima kunye nokugqithisa kakhulu. Isebenza njengokhuselo olusebenzayo lwe-backup, oluqala xa i-primary pr...
jonga iinkcukacha 
Uthelekiso lobuchwephesha: I-Isolation Transformer vs. i-Ordinary Transformer
2025-08-26
Iinjongo Eziphambili Zokusebenza IiTransformers Eziqhelekileyo Zenzelwe ngokuyintloko ukuguqulwa kwevoltage (ukunyuka/ukwehla), kunye nomlinganiselo wokujika ongalinganiyo phakathi kwee-windings eziphambili/zesibini. Injongo yazo esisiseko kukuguqulwa kwevoltage ye-AC ukuhlangabezana ne-lo...
jonga iinkcukacha 
IINZUZO ZOKUGUQULA EZIFAKWE KWI-PAD YESIGABA ESINYE?
2025-08-25
Yintoni i-transformer ene-pad yesigaba esinye? Isitishi sohlobo lwebhokisi sikwabizwa ngokuba yi-substation yohlobo lwebhokisi, isitishi sohlobo lwebhokisi okanye isitishi sohlobo lwebhokisi, esibizwa ngokuba yi-"box-type transformer". I-transformer enokwahlulwa kombane phakathi kwe-input winding kunye...
jonga iinkcukacha 
Iingenelo kunye nokungalungi kwee-transformers ezintywiliselwa kwi-oyile
2025-08-22
Iingenelo 1.Ukupholisa Okugqwesileyo kunye nokuTshiswa koBushushuIitransformer ezintywilisiweyo kwioyile zisebenzisa ioyile yokukhusela ukufunxa nokudlulisa ubushushu ngokufanelekileyo. Umthamo ophezulu wobushushu weoyile kunye nokuqhuba kobushushu kwenza ukusebenza okuzinzileyo phantsi kobunzima...
jonga iinkcukacha 
Itanki yetransformer - funda ngeentlobo, izinto, nokunye!
2025-08-21
Iitanki zetransformer ziyinxalenye ebalulekileyo kodwa edla ngokunganakwa kwiziseko zombane. Ezi ndawo ziqinileyo zidlala indima ebalulekileyo ekuqinisekiseni ukusebenza okuthembekileyo kweetransformer zamandla. Kodwa yintoni eyahlula iintlobo ezahlukeneyo zeetanki zetransformer, kunye...
jonga iinkcukacha 
Indima yeeFlanges kwiTransformers: Iinkcukacha ezibalulekileyo ekufuneka uzazi
2025-08-20
Iiflanges zinokubonakala ngathi zizinto ezilula, kodwa zidlala indima ebalulekileyo ekusebenzeni nasekugcinweni kweetransformers. Ukuqonda iintlobo zazo kunye nokusetyenziswa kwazo kunceda ekuqaqambiseni ukubaluleka kwazo ekuqinisekiseni ukusebenza okuthembekileyo nokusebenzayo kweetransformer. ...
jonga iinkcukacha 
Izixhobo zokutshintsha
2025-08-20
Iisekethe zombane zilawula umthamo womthwalo omiselwe kwangaphambili ngokwendlela eziyilwe ngayo. Kufuneka zilawulwe ukuze kuthintelwe ukuba umbane ogqithisileyo ungagqithisi kakhulu kwiintambo kwaye ugqithise kakhulu inkqubo.












