Leave Your Message
Iindidi zeendaba
Iindaba Eziphambili

Iindaba

Iitransformer ezifakwe kwi-pad ze-JZP ezineSigaba esinye: Ubunjineli obuchanekileyo bokusasazwa kwamandla okuthembekileyo

Iitransformer ezifakwe kwi-pad ze-JZP ezineSigaba esinye: Ubunjineli obuchanekileyo bokusasazwa kwamandla okuthembekileyo

2025-10-09

Iitransformer zeJZP ezine-pad zesigaba esinye zenzelwe ukudlula imigangatho yehlabathi ngelixa zibonelela ngokuguquguquka okungenakuthelekiswa nanto kunye nokuqina kwiimfuno ezahlukeneyo zokusasazwa kwamandla. Zenzelwe ukuthobela nokugqitha ​Imigangatho ye-ANSI, IEEE, DOE, CSA, kunye ne-NEMA, ezi transformers ziquka iimpawu zokhuseleko eziphambili kunye nolwakhiwo oluqinileyo, ziqinisekisa ukusebenza kakuhle kwizicelo zoshishino, zorhwebo, kunye nezindlu.

jonga iinkcukacha
I-JZP Power Transformer iza kubonisa izinto ezintsha kwi-Electricity Transformation Canada ngo-2025

I-JZP Power Transformer iza kubonisa izinto ezintsha kwi-Electricity Transformation Canada ngo-2025

2025-09-30

Njengomdlali okhokelayo kwishishini le-power transformer, i-JZP Power Transformer ivuya kakhulu ukuvakalisa ukuba ithatha inxaxheba kwiUtshintsho loMbane eKhanada ngo-2025, umsitho ophambili ozinikele ekubumbeni ikamva lecandelo lombane eKhanada. Lo mboniso uza kwenzeka ukususelaOkthobha 6–8, 2025, kwiIziko le-Enercare eToronto, eOntario, kwaye i-JZP Power Transformer iza kubonisa izisombululo zayo ezisemgangathweni aphaIbhuthi 609.

jonga iinkcukacha
IiVolthi eziphezulu, eziphakathi, ezisezantsi, kunye neziphezulu kakhulu zihlelwa njani kwiinkqubo zamandla?

IiVolthi eziphezulu, eziphakathi, ezisezantsi, kunye neziphezulu kakhulu zihlelwa njani kwiinkqubo zamandla?

2025-09-29

Ukuhlelwa kwamanqanaba ombane kwiinkqubo zamandla kubalulekile ekuqinisekiseni ukuhanjiswa kwamandla, ukusasazwa, kunye nokhuseleko olufanelekileyo. Amanqanaba ombane amisela indlela umbane othuthwa ngayo kwiigridi, alungelelaniswe ukuze kube nokwenzeka ubuchwephesha noqoqosho, kwaye ahlengahlengiswe kwiindlela ezahlukeneyo zokusebenza. Eli nqaku liphonononga iikhrayitheriya kunye nemigangatho elawula olu hlulo, kugxilwe kakhului-voltage ephezulu (i-HV),i-voltage ephakathi (MV),i-voltage ephantsi (LV)​kunyei-voltage ephezulu kakhulu (UHV)Ukuhlelwa kwamanqanaba ombane kwiinkqubo zamandla kubalulekile ekuqinisekiseni ukuhanjiswa kwamandla, ukusasazwa, kunye nokhuseleko olufanelekileyo. Amanqanaba ombane amisela indlela umbane othuthwa ngayo kwiigridi, alungelelaniswe ukuze kube nokwenzeka ubuchwephesha noqoqosho, kwaye ahlengahlengiswe kwizicelo ezahlukeneyo. Eli nqaku liphonononga iikhrayitheriya kunye nemigangatho elawula olu hlu, kugxilwe kakhului-voltage ephezulu (i-HV),i-voltage ephakathi (MV),i-voltage ephantsi (LV)​kunyei-voltage ephezulu kakhulu (UHV).

jonga iinkcukacha
I-JZP Power Transformer: Ukunika Amandla Ikamva kwi-ENLIT Europe 2025

I-JZP Power Transformer: Ukunika Amandla Ikamva kwi-ENLIT Europe 2025

2025-09-24

Njengomvelisi ophambili ogxile kwiitransformer ze-voltage ephakathi nephezulu, i-JZP Power Transformer ivuya kakhulu ukuvakalisa ukuba sithatha inxaxheba kwi-ENLIT Europe 2025—umsitho ophambili kwilizwekazi wezinto ezintsha zamandla. Ukususela nge-18-20 kaNovemba 2025, siza kubonisa izisombululo zethu ezisemgangathweni kwiZiko leMiboniso laseBilbao (48100 Bilbao, Bizkaia, eSpain). Sityelele eBooth 3.F122 ukuze ufumane indlela esibumba ngayo ikamva lokudluliselwa kwamandla kunye nokusasazwa kwawo.

jonga iinkcukacha
Joyina nathi kwi-2025 3E XPO!

Joyina nathi kwi-2025 3E XPO!

2025-09-24

Kwindawo eguquguqukayo yeziseko zamandla zehlabathi, i-JZP imele njengeqela eliphambili eligxile kwi-transformers ze-voltage ephakathi nephezulu—umqolo wokudluliselwa kwamandla, ukusasazwa, kunye nokusetyenziswa kwawo ngokufanelekileyo. Ngolwazi lwamashumi eminyaka, ubuchwepheshe obuphambili, kunye nokuzibophelela okungagungqiyo kumgangatho, sixhobisa amashishini, iinkonzo, kunye neeprojekthi kwihlabathi liphela ukuze sifezekise izisombululo zamandla ezinokuthenjwa, ezizinzileyo, nezingabizi kakhulu.

 

jonga iinkcukacha
Isitshixo seTransformer esiPhakathi nesiPhezulu: Isikhokelo soBugcisa

Isitshixo seTransformer esiPhakathi nesiPhezulu: Isikhokelo soBugcisa

2025-09-23

Iswitshi sisebenza njengomqolo weenkqubo zamandla ze-voltage ephakathi nephezulu (MV/HV), senza imisebenzi emithathu ebalulekileyo kwiitransformer:

  • Ukusasazwa koMbane: Ihambisa umbane ukusuka kwiitransformer ukuya kwimithwalo ngezixhobo zokuphakela, iibhasi, kunye nezixhobo zokukhusela.
  • Ukukhuselwa kweMpazamo: Iphazamisa ukusebenza kwe-currents ngaphakathi kwee-milliseconds (umz., amandla okuphuka kwe-short-circuit engama-31.5kA–40kA) ukuthintela umonakalo kwizixhobo.
  • Ukuzahlula kuKhuseleko: Iqinisekisa ukugcinwa okukhuselekileyo ngokusebenzisa iindlela zokudibanisa oomatshini kunye neendlela zokumisa umhlaba.

Umzekelo, inkqubo ye-12kV ifuna ubuncinci bokususwa kwe-phase-to-ground kwe-125mm (i-air-insulated) okanye i-40mm (i-gas-insulated) ukuthintela ukungqubana

.

jonga iinkcukacha
Uhlalutyo oluneenkcukacha lweeM&H Voltage Power Electronic Transformer Types, Structure Configurations, kunye neeKey Parameters

Uhlalutyo oluneenkcukacha lweeM&H Voltage Power Electronic Transformer Types, Structure Configurations, kunye neeKey Parameters

2025-09-22

Uhlalutyo oluneenkcukacha lweeM&H Voltage Power Electronic Transformer Types, Structure Configurations, kunye neeKey Parameters

jonga iinkcukacha
Uphononongo malunga neTopology kunye nezicelo zoLawulo lweeTransformers ze-Electronic Power ze-Medium-High Voltage III

Uphononongo malunga neTopology kunye nezicelo zoLawulo lweeTransformers ze-Electronic Power ze-Medium-High Voltage III

2025-09-18

I-topology ye-Neutral Point Clamped (NPC) multilevel ibonisiwe. Ngaphandle kwe-topology ye-NPC ene-diode-clamped, ii-topology ze-NPC ziquka uhlobo lwe-flying capacitor kunye nohlobo lwe-hybrid clamped, phakathi kwezinye. Nangona kunjalo, ngenxa yomthamo omkhulu we-capacitor, ii-topology ze-NPC zisasebenzisa kakhulu izixhobo zokutshintsha ezingasebenziyo okanye ezisebenzayo zokucinezela. Ukuthatha i-topology ye-diode-clamped multilevel njengomzekelo, kwi-topology yesigaba se-rectifier esinezigaba ezintathu, umlenze ngamnye wesigaba uqulathe ii-transistors zokutshintsha ezicascaded kunye nee-diode zokubopha, eziqhagamshelwe ngokuhambelana nebhasi enye ye-DC ene-voltage ephezulu. Uncwadi lucebise i-topology ye-PET yesigaba esinye enesigaba sokulungisa kusetyenziswa isekethe ene-diode-clamped enezigaba ezine. Ibhasi enye ye-DC ene-voltage ephezulu ilandelwa yi-input-series-output-parallel DABs, njengoko kubonisiwe. Le topology inokwandiswa ibe yisakhiwo sesigaba sesithathu, kwaye inani lamanqanaba e-voltage linokutshintshwa ngokusekelwe kumanqanaba e-voltage amelana nesixhobo kunye nenqanaba le-voltage esecaleni ye-voltage ephezulu. Njenge-topology ye-MMC, i-topology ye-NPC ingasetyenziswa nakwisigaba sokuzihlukanisa, idibanisa ibhasi ye-DC ene-voltage ephezulu kwi-transformer yokuzihlukanisa, njengoko kubonisiwe. Uncwadi lusebenzise i-converter ye-NPC ene-diode-clamped yamanqanaba amathathu kwicala le-voltage ephezulu ye-converter ye-LLC resonant, iqinisekisa kwi-prototype ye-166kW/2kV ~ 400V. Uncwadi lusebenzise isekethe ye-NPC ene-diode-clamped yamanqanaba amathathu kwi-DAB yezigaba ezintathu, ifezekisa i-voltage ye-DAB efanelekileyo kunye neempawu zangoku.

jonga iinkcukacha
Uphononongo malunga neTopology kunye nezicelo zoLawulo lweeTransformers ze-Electronic Power ze-Medium-High Voltage II

Uphononongo malunga neTopology kunye nezicelo zoLawulo lweeTransformers ze-Electronic Power ze-Medium-High Voltage II

2025-09-18

Ii-topologies ze-PET zahlukile kakhulu. Ngokusekelwe kwinani lamanqanaba okuguqulwa kwamandla, anokwahlulwahlulwa abe ziintlobo zesigaba esinye, izigaba ezibini, kunye nezigaba ezintathu [7]. Izakhiwo zezigaba ezibini ziquka ezo zinebhasi ze-DC ezine-voltage ephezulu kunye ne-voltage ephantsi, njengoko kubonisiwe kuMfanekiso 1.

jonga iinkcukacha
Uphononongo malunga neTopology kunye nezicelo zoLawulo lweeTransformers ze-Electronic Power Voltage eziPhakathi nePhezulu I

Uphononongo malunga neTopology kunye nezicelo zoLawulo lweeTransformers ze-Electronic Power Voltage eziPhakathi nePhezulu I

2025-09-16

Ngesiphakamiso sengcamango ye-intanethi yamandla kunye nokusetyenziswa ngokubanzi kwezobuchwepheshe ezinxulumene negridi ekrelekrele, umlinganiselo wemithombo yamandla avuselelekayo njengamandla omoya kunye ne-photovoltaic kwinkqubo yamandla ekhoyo uya kwanda kakhulu. Oku kubonisa ukuba iigridi zamandla ezizayo ziya kuba nobuchule ngakumbi kwaye ziguquguquke. Kwi-intanethi yamandla, njengoko umlinganiselo wabasebenzisi abasasaziweyo kunye nezixhobo zamandla unyuka, ukuhanjiswa kombane kufuna amandla alawulekayo kakhulu. Kwiinethiwekhi zokusasazwa ezikrelekrele, igridi kufuneka igcine umbane ozinzileyo nosemgangathweni ophezulu ngelixa idibanisa inani elikhulu lemithombo yamandla avuselelekayo asasaziweyo kunye nokubeka esweni/ukulawula iimeko zokusebenza kwegridi. Ezi mfuno zibeka iimfuno ezingqongqo kubuchule bezixhobo zegridi yamandla, ngelixa ii-transformers zesiqhelo zamandla zijongene nemida yokusebenza.

jonga iinkcukacha