Leave Your Message

IiTransformers ezifakwe kwi-Pad ze-500kVA ezisebenza kakuhle kakhulu kwiShishini

I-500kVA Three-Phase Pad-Mounted Transformer sisixhobo sokusasaza amandla esisebenza kakuhle kakhulu esenzelwe iipaki zoshishino, izakhiwo zorhwebo, kunye neeprojekthi zeziseko zophuhliso. Iguqula i-voltage ephakathi (11kV) ibe yi-voltage ephantsi (400V) isebenzisa ukupholisa okufakwe kwi-oyile (ONAN), okwenza ukuba ifaneleke ukufakwa ngaphandle. Le transformer idibanisa ukuthembeka, ukugcinwa okuphantsi, kunye nokukwazi ukugqithisa okuqinileyo ukuqinisekisa ukunikezelwa kombane okuzinzileyo kwiindawo ezifuna amandla amaninzi.

    Iimpawu zesakhiwo

    Isiseko​
    Imicu yentsimbi yesilicon eqengqelekayo ebandayo: Ingena kakhulu emoyeni ene-laminated insulation ukunciphisa ilahleko zamandla e-eddy.
    Uyilo lwemilenze emihlanu olunezigaba ezintathu: Lunciphisa impedance ye-zero-sequence kwaye lucinezela iiharmonics.
    Iiwindings
    Ukujika kweVoliti ephezulu: I-Copper foil ene-insulation yephepha le-Nomex ukuze ikwazi ukumelana ne-voltage ephezulu.
    Ukujika kweVolthi ephantsi: Ulwakhiwo lwesilinda oluneeleya ezininzi lokumelana nokujikeleza okufutshane okuphuculweyo.
    Itanki kunye nokuPholisa​
    Amaphiko erediyetha ane-corrugated: Ukupholisa i-convection yendalo ngaphandle kweefeni zangaphandle.
    Uyilo oluvalwe ngokupheleleyo: Luthintela ukungcoliswa kweoyile kunye nokungcola.
    Inkqubo yokukhusela ubushushu​
    Ioyile yeminerali (esemgangathweni) okanye ioyile ye-FR3 ester (eyongamela indalo), ebonelela ngokufudumala, ukupholisa, kunye nokuphela kwe-arc.
    Inqanaba lokukhupha elingaphelelanga ≤50pC (ihambelana ne-IEC 60076).
    I-Transformer efakwe kwi-Cooper Oil eQokelelweyo i-High Frequency 10001I-Transformer Efakwe kwi-Cooper Oil eQokelelweyo i-High Frequency 10002I-Transformer efakwe kwi-Cooper Oil eQokelelweyo i-High Frequency 10003
    IiTransformers ezifakelwe kwi-500kVA-ezisebenza kakuhle kakhulu-ezine-Pad yezigaba ezintathu
    • IiTransformers-ezifakelwe kwi-500kVA-ezinezigaba ezintathu-ezisebenza kakuhle kakhulu kwiShishini (1)
    • IiTransformers-ezifakelwe kwi-500kVA-ezinezigaba ezintathu-ezisebenza kakuhle kakhulu kwiShishini (2)
    • IiTransformers-ezifakelwe kwi-500kVA-ezinezigaba ezintathu-ezisebenza kakuhle kakhulu kwiShishini (3)
    • IiTransformers-ezifakelwe kwi-500kVA-ezinezigaba ezintathu-ezisebenza kakuhle kakhulu kwiShishini (4)
    • IiTransformers-ezifakelwe kwi-500kVA-ezinezigaba ezintathu-ezisebenza kakuhle kakhulu kwiShishini (5)
    • IiTransformers-ezifakelwe kwi-500kVA-ezinezigaba ezintathu-ezisebenza kakuhle kakhulu kwiShishini (6)
    I-Transformer Efakwe kwi-Cooper Oil01

    Izicelo

    Iipaki zeShishini
    Inika amandla oomatshini abanzima, imigca yokuvelisa (umz., iipress, iicrane), kwaye ixhasa ukugqithisa okwethutyana elifutshane.
    Iindawo zorhwebo​
    Isasaza umbane wokukhanyisa, iinkqubo ze-HVAC, iilifti, kunye nokhuseleko kwiindawo ezinkulu, iihotele, kunye neeofisi.
    Iiprojekthi zeZiseko zoPhuhliso
    Izitishi zikaloliwe, izikhululo zokucoca amanzi amdaka, kunye neenkqubo zamandla ezikhululo zeenqwelo-moya.
    Ukuphuculwa kweGrid yasemaphandleni​
    Ithatha indawo yeetransformer ezigugileyo ukuphucula ukuthembeka kunye nokusebenza kakuhle kwamandla.

    Iingenelo eziphambili

    Ukuthembeka okuphezulu
    Iphumelela uvavanyo lwe-IEC 60076 lokumelana ne-short-circuit, iqinisekisa uzinzo ngexesha lokungasebenzi kakuhle kwegridi.
    Itanki evalwe ngokupheleleyo yandisa ubomi beoyile (ayigcinwa ixesha elide ukuya kuthi ga kwiminyaka eli-10).
    Ukonga Amandla​
    Ukulahlekelwa ngumthwalo okuphantsi kunciphisa iindleko zokusebenza, kuhambelana nemigangatho ye-IEEE C57.12.
    Ukuguquguquka kokusingqongileyo​
    Isebenza kumaqondo obushushu aphezulu (-40℃ ukuya ku-+55℃) nakwiindawo eziphakamileyo (≤3,000m).
    Iinketho eziBulumko
    Ixhasa ukuhlanganiswa kwe-IoT kunye nezinzwa zobushushu, iimonitha zenqanaba leoyile, kunye neealamu ezikude.

    Ukuqinisekisa umgangatho

    Iyunithi nganye ivavanywa ngokuqatha, kuquka:
    Uvavanyo lokumelana nobushushu kunye noxinzelelo lwe-impulse.
    Ukulinganiswa kokulahlekelwa ngumthwalo kunye nokulahleka komthwalo.
    Ukuqinisekiswa kokumelana nokujikeleza okufutshane.
    Iqinisekiswe yi-ISO 9001, ISO 14001, kunye ne-KEMA ngenxa yokuthobela imithetho yehlabathi.

    Izikhokelo zoKhetho

    Iimfuneko zoMthwalo​
    Umthwalo Oqhubekayo: Khetha ii-transformers ezilinganiswe ≥125% yomthwalo ophezulu olindelekileyo (umz., i-500kVA yokusetyenziswa rhoqo kwe-400kVA).
    Umthwalo Ogqithisileyo Wexesha Elifutshane: Usetyenziso lwemizi-mveliso lunokufuna umthamo womthwalo oyi-150% imizuzu engama-30.
    Iimeko zeNdalo​
    Isitshizi Sokufutha/Ityuwa: Iindawo ezikunxweme zifuna izinto zokukhusela ukubola.
    Iimfuneko zeNdawo: Qinisekisa ukuba kukho indawo engaphezulu kwe-1.5m ejikeleze i-transformer ukuze igcinwe icocekile.
    Ukuthobela imithetho​
    Ihlangabezana ne-IEC 60076, i-IEEE C57.12, i-GB 1094 (eTshayina), kunye ne-ATEX kwiindawo ezinobungozi.
    Ukukhetha ioyile
    Ioyile yeMineral: Ixabiso layo liphantsi kwiindawo ezisemgangathweni.
    Ioyile ye-Ester ye-FR3: Ayitshisi kwaye ayingeni bungozi kwiindawo ezinobuthathaka (umz., amaziko edatha).

    Ukufakwa kunye nokugcinwa​

    Ufakelo​
    Sebenzisa isiseko esilinganayo esinokumelana nokumisa umhlaba ≤4Ω.
    Iintambo zokunxibelelana zixhasa iintambo eziyi-185mm² (umnyango ongezantsi okanye osecaleni).
    Ukugcinwa Kwemihla Ngemihla​
    Ngekota: Jonga inqanaba leoyile, umbala, kunye nokuvuza.
    Qho ngonyaka: Vavanya ukumelana nobushushu (2,500V megohmmeter) kwaye wenze uhlalutyo lwe-oyile chromatography.
    Ukusombulula iingxaki
    Ubushushu obugqithisileyo: Hlola ukuvaleka kweradiator okanye imithwalo engaqhelekanga.
    Ukukhupha okuncinci: Sebenzisa i-oyile chromatography ukuze ubone iziphene zokufakelwa kwangaphakathi.
    I-Transformer Efakwe kwi-Oyile yeCooper02I-Transformer Efakwe kwi-Oyile yeCooper03I-Transformer efakwe kwi-oyile yeCooper04I-Transformer Efakwe kwi-Oyile yeCooper05

    Kutheni ukhethe thina

    I-JIEZOU POWER, umyili oqeqeshiweyo, umenzi kunye nomfaki wesisombululo senkqubo yamandla kwihlabathi liphela, yasekwa ngonyaka we-1989, ithatha indawo ye-200,000 square metres.
    I-JIEZOU POWER, ilawula ikakhulu iiprojekthi zegridi yombane, i-500KV EPC, isikhululo sombane samanzi se-230KV, isikhululo sombane se-115KV, njl.
    Ifektri yeJIEZOU POWER inokwenza i-transformer yosasazo yohlobo lweoyile kunye nohlobo olomileyo, i-max 500KV 480MVA power transformer, iGIS, iswitchgear, i-substation, ngokusekelwe kumgangatho we-ANSI/IEEE/DOE2016/CSA/IEC60076.
    I-JIEZOU POWER ifumana isiqinisekiso se-ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Kude kube ngunyaka ka-2023, iinkampani zamasebe zehlabathi kunye neefektri zisasazwa eMelika, eKhanada, eDubai, eDominican Republic, ePhilippines, iifektri zamasebe aseTshayina kunye neenkampani zikwisixeko saseBengBu, kwisixeko saseFengYang, kwisixeko saseHaiAn, kwisixeko saseTaiZhou, kwisixeko saseSuZhou, kwisixeko saseShenYang, kwisixeko saseFoShan.
    Xa sijonga kwixesha elizayo, umbono kaJIEZOU POWER kukuba ngumboneleli wezisombululo zenkqubo yamandla othembekileyo, ukusombulula imingeni yokulawula amandla engxamisekileyo kwihlabathi liphela, ukukhawulezisa utshintsho lweplanethi ukuya kumandla avuselelekayo. Ukuze wonke umntu abe nobomi obungenakhabhoni kwaye obukhanyayo. Ngenxa yoku, siza kwenza konke okusemandleni ethu ukwenza imizamo.
    I-Transformer Efakwe kwi-Oyile yeCooper06I-Transformer Efakwe kwi-Cooper Oil07I-Transformer Efakwe kwi-Oyile yeCooper08I-Transformer Efakwe kwi-Oyile yeCooper09

    Buza Ngoku!

    Ukuba unemibuzo malunga neemveliso zethu okanye uluhlu lwamaxabiso, nceda usishiyele i-imeyile yakho kwaye siya kuqhagamshelana nathi kwiiyure ezingama-24.

    Leave Your Message