I-JZP igqwesile ekwenzeni ii-transformers ze-ANSI/IEEE/UL, ibonisa ubuchule obumangalisayo kunye nobuchule kwiimarike zaseMntla naseMzantsi Melika. Banikezela ngee-transformers ezingama-25 kVA ezine-pole-mounted single-phase, ezinokuyilwa, ziveliswe, kwaye zenziwe ngokwezifiso ukuze zihlangabezane nemigangatho eyahlukeneyo yamazwe ngamazwe. Ukuzibophelela kwe-JZP ekugqweseni kubenza babe liqabane elithembekileyo kuzo zonke iimfuno ze-transformer eMelika nakwamanye amazwe.

I-25kVA 19.92kV Isiguquli seSigaba esinye
I-DL-25/19.92/0.24(0.12), yitransformer eyenzelwe wena enesigaba esinye exhonywe kwipali.
I-transformer ye-25 kVA ene-single-phase pole-mounted isebenzisa izinto zokujika ze-aluminium ezikumgangatho ophezulu kwiindawo zayo zombini ezine-voltage ephezulu nephantsi, iqinisekisa ukusebenza okuphezulu kunye nokuthembeka. Ngexabiso le-impedance le-2%, ineqela leVector le-Ii0 kunye ne-polarity eyi-Subtractive, ephucula ukusebenza kwayo.
I-voltage ephezulu ye-transformer enamanqanaba amahlanu ahlukeneyo olawulo lwe-voltage, inika ukuguquguquka okumangalisayo, ngelixa uluhlu lolawulo lwe-voltage lwe-19.92kV±2×2.5% luqinisekisa uzinzo oluzinzileyo nangona kukho ukuguquguquka.

I-25kVA 7.2(12.47)kV/4.8(8.32)kV Isiguquli seSigaba esinye
I-transformer ye-25 kVA ene-single phase pole ine-design ye-voltage ephezulu kabini. Oku kwenza ukuba kukhethwe i-voltage ephezulu ukusuka kwi-7.2kV okanye kwi-4.8 kV ngaphandle kokuphazamiseka, ihambelana ngokuchanekileyo neemfuno ezahlukeneyo zezixhobo zomthwalo, inika ukuguquguquka okungenakuthelekiswa nanto.
I-transformer ibandakanya inkqubo yokupholisa ye-ONAN esebenzayo, encediswa yioyile yeminerali engena-PCB engu-45#, eqinisekisa ukhuseleko kunye noxanduva lokusingqongileyo.
Isebenzisa iqela levector le-Ii6 elithembekileyo kunye ne-additive polarity, i-transformer ime njengeyona nto iphambili yokusebenza kunye nokuthembeka. Izixhobo eziphambili ziquka i-bushing enye ye-high voltage, ii-bushings ezintathu ze-low voltage, i-switch enye ye-dual voltage, i-1 pressure relief, i-1 H2 terminal, ii-copper strips ezimbini, ii-tank grounds ezintathu, ii-support lugs ezimbini, ii-lift lugs ezimbini, kunye nee-cover clamps ezi-6, ezingqina uyilo lwayo oluphambili kunye nokusebenza kwayo.

I-25kVA 17.32kV Isiguquli seSigaba esinye
Le transformer inevolthi yokuqala eyi-17.32 kV kunye nevolthi yesibini eyi-230V, yenziwe ngononophelo ukuhlangabezana neemfuno ezithile zomthengi.
Njengoko i-copper winding isembindini wayo, le transformer iqinisekisa ukusebenza okuphezulu kunye nokuthembeka. Isebenza kwi-frequency ye-50 Hz kwaye ineqela leVector le-Ii0 eline-polarity eyongezelelweyo, iqinisekisa ukuhlanganiswa okungenamthungo kwiinkqubo zamandla ezahlukeneyo.
I-transformer enoluhlu lolawulo lwe-17.32kV±2×2.5%, evumela ukuphuma kwe-voltage echanekileyo nezinzileyo naphantsi kweemeko zomthwalo ezahlukeneyo.