+86 18068001229 01
Isiguquli samandla se-35MVA 115kV esinezigaba ezi-3
Ingcaciso yeMveliso
I-35MVA 115kV 3 Phase Power Transformer, sisixhobo sombane esisemgangathweni ophezulu esenzelwe ukubonelela ngezicelo ezibalulekileyo kwiiprojekthi zamandla avuselelekayo. Sakhiwe ukuhlangabezana nemigangatho ephezulu yokusebenza, ukuthembeka, kunye nokusebenza kakuhle kwamandla, ukuqinisekisa ukusebenza kakuhle kwiinkqubo zamandla zesiqhelo kunye nezo zivuselelekayo.
Iimpawu eziphambili kunye nokusebenza
Ukuthobela i-IEEE C57.12.00: I-transformer ye-35MVA 115kV ithobela imigangatho yeshishini lamazwe ngamazwe, iqinisekisa umgangatho ophezulu kunye nokusebenza.
Ukulahleka okuphantsi kunye nokusebenza kakuhle okuphezulu: Yenzelwe ukuba ilahleko ephantsi yomongo kunye nobhedu, le transformer inciphisa kakhulu ukusetyenziswa kwamandla, inegalelo ekuzinzeni nasekusebenziseni kakuhle iindleko.
Ukunciphisa Ukukhupha Okungaphelelanga kunye nengxolo: Yenzelwe ukukhupha igesi kancinci (PD) kunye nokukhupha ingxolo, iqinisekisa ukusebenza okuzolileyo ngelixa igcina uzinzo lwexesha elide.
Ukumelana neSijikelezo esifutshane: I-transformer yenzelwe ukumelana nemisinga ephezulu yempazamo, nto leyo ephucula ukhuseleko kunye nokuqina kwenkqubo.
Uyilo Olungenawo Ukuvuza: Ngokwakhiwa okuqinileyo, le transformer yenzelwe ukuthintela ukuvuza kweoyile, ukuphucula ukhuseleko lokusingqongileyo kunye nokuthembeka kwenkqubo.

Isiguquli samandla se-35MVA 115kV
Izixhobo eziPhambili kunye noKwakha
1. Izinto ezingundoqo kunye neCoil: Umongo wetransformer wakhiwe ngentsimbi yesilicon esemgangathweni ophezulu, ekwaziyo ukungena ngokukhawuleza, enendlela yokudibanisa ephucukileyo kwi-step-lap jointing kwi-45° ukuze kubekho i-magnetic flux efanelekileyo. Umphezulu ugqunywe ngomaleko okhethekileyo wokulwa nokubola, okunciphisa ilahleko ezingenamthwalo kwaye unciphisa amanqanaba engxolo.
2. Ingxolo Ephantsi kunye Nokuqina Okuphuculweyo: I-coil kunye ne-core assembly ziquka iimpawu zoyilo ezizimeleyo ezifana ne-core bracing kunye nokusetyenziswa kwee-transposed conductor wires, ukuqinisekisa ukuveliswa kwengxolo encinci kunye nozinzo lwexesha elide.
Itshintshi yeTap ekwi-Load (OLTC)
1. I-transformer ye-35MVA ixhotyiswe nge-On-Load Tap Changer (OLTC) kwicala le-voltage ephezulu, evumela ukulawulwa kwe-voltage kuluhlu lwe-115kV ± 8 × 0.625%.
2. I-OLTC ibandakanya umlondolozi, isalathisi senqanaba leoyile, i-Buchholz relay, kunye ne-self-regenerating breather, zonke ezi negalelo ekusebenzeni okukhuselekileyo nokuzinzileyo kwe-transformer.
Iimpawu zoKhuseleko kunye noKhuseleko
1. Ukhuseleko lweGesi kunye noLwahlulo: I-transformer ixhotyiswe ngokhuseleko lwegesi kunye nokhuselo lolwahlulo ukuqinisekisa ukusebenza ngokukhuselekileyo kunye nokufunyanwa kweempazamo kwangethuba.
2. Ukubeka esweni irelay: Le yunithi inerelay zangaphakathi nezangaphandle ezibangela ii-alamu kwaye ziqalise ukukhubeka ngokuzenzekelayo ukuba kukho naluphi na utshintsho olungaqhelekanga lwegesi okanye ioyile olufunyenweyo.
3. Ukubeka iliso kwiNqanaba leoyile: Izikhombisi zenqanaba leoyile zibeka iliso kwimeko yetanki yeoyile, kunye nee-alamu ezivulwa ukuba inqanaba leoyile liwela ngaphaya koluhlu oluchaziweyo, ukuqinisekisa ukugcinwa kweoli ngokufanelekileyo.
Ivalvu Yokunceda Uxinzelelo
Xa kwenzeka ukuba igesi yangaphakathi iqokeleleke ngokukhawuleza ngenxa yeemeko zempazamo, i-transformer ixhotyiswe ngevalvu yokunciphisa uxinzelelo. Le nkqubo ikhupha igesi engaphezulu, ithintela uxinzelelo olugqithisileyo kwaye ivumela igumbi lolawulo ukuba lithathe inyathelo ngoko nangoko ngokubangela ukuba itshintshe ngokuzenzekelayo.
Ukubeka iliso kubushushu
Izikhombisi zoBushushu beOyile kunye nokujika: I-transformer ixhotyiswe ngee-sensors zokujonga ubushushu beoyile kunye nokujika. Ukuba ubushushu budlula i-95°C, isignali ye-alamu ithunyelwa kwigumbi lokujonga elikude. Ukuba ubushushu budlula i-105°C, i-transformer iya kukhubeka ngokuzenzekelayo ukuthintela ubushushu obugqithisileyo kunye nomonakalo onokubakho.
Inkqubo yokupholisa
I-transformer inenkqubo yokupholisa enamanqanaba amabini:
Inqanaba loku-1: Ifeni yokuqala yokupholisa iyasebenza xa ubushushu bokujika budlula ama-75°C.
Inqanaba lesi-2: Ifeni yesibini iyasebenza xa ubushushu bufikelela kuma-80°C.
Xa ubushushu buhla ngaphantsi kwama-75°C, iifeni ziyazicima ngokuzenzekelayo, ziqinisekisa ukupholisa okusebenzayo kunye nokunciphisa ukusetyenziswa kwamandla.
I-Self-Regenerating Breather
Zombini iziko eliphambili le-transformer kunye ne-conservator ye-tap changer zixhotyiswe nge-breather ezivuselelayo (uphawu lweQualitrol). I-breather isebenzisa i-desiccant eyakhelwe ngaphakathi (i-silica gel) efunxa umswakama kwaye ivuselele ngokufudumeza, ithintela umswakama nomoya ukuba ungangeni kwi-transformer. Oku kuqinisekisa ukuba i-insulation ihlala yomile, ixhasa uzinzo lokusebenza kwexesha elide kwe-transformer.
Izicelo
1. Iiprojekthi zamandla avuselelekayo (iLanga, uMoya, njl.njl.)
2. Ukusasazwa kwamandla emizi-mveliso
3. Uzinzo lweGridi
4. Iinkqubo zamandla ezithembeke kakhulu

Isiphelo
I-35MVA 115kV Three-Phase Power Transformer sisisombululo esiphambili nesisebenza kakuhle kwiinkqubo zanamhlanje zokusasazwa kwamandla, ingakumbi kumacandelo amandla avuselelekayo. Ngezixhobo eziphambili, iimpawu zokhuseleko eziphezulu, kunye noyilo lokonga amandla, inika ukusebenza kakuhle okuphezulu, ukuthembeka, kunye nobomi benkonzo ende. Le mveliso ibonisa ukuzibophelela kwe-JZP Transformer ekunikezeni izisombululo ezintsha nezisemgangathweni ukuhlangabezana neemfuno zekamva lamandla azinzileyo.
Ukulungele Ukunika Amandla Ikamva Lamandla?
Qhagamshelana nathi namhlanje ukuze ufunde okungakumbi malunga nendlela i-35MVA 115kV Three-Phase Power Transformer enokuphucula ngayo iiprojekthi zakho zamandla ahlaziyekayo kwaye iqinisekise ukusasazwa kwamandla okuthembekileyo nokusebenzayo.

Buza Ngoku!
Ukuba unemibuzo malunga neemveliso zethu okanye uluhlu lwamaxabiso, nceda usishiyele i-imeyile yakho kwaye siya kuqhagamshelana nathi kwiiyure ezingama-24.