+86 18068001229 01
I-2000kVA Isiguquli Esifakelwe Iiphedi Ezithathu
Ingcaciso yeMveliso
Iitransformer ze-JZP Transformer ze-2000kVA, ezingama-34.5kV ezifakwe kwi-pad zifakwa kwiNkqubo yokuGcina amandla eBhetri (i-BESS) eKern County, eCalifornia, apho zibonelela ngamandla ancedisayo anokuthenjwa ukuxhasa izixhobo ezahlukeneyo kwisikhululo sokugcina amandla. Ezi transformer zigqityiwe ngoMeyi 2024 kwaye zathunyelwa kubathengi baseMelika, zibalulekile ekuqinisekiseni ukusebenza okungaphazanyiswayo kunye nolawulo olufanelekileyo lokugcina amandla.
01020304050607
| Amaqondo obushushu aphakathi | Ubuncinci -15.0°C, Ubuninzi obuyi-41.0°C, ubuninzi obuyi-24 iiyure obuyi-33.0°C |
| Ukuphakama | Iinyawo ezingaphantsi kwama-3300 |
| Iimeko zenyikima: | Udidi loMngcipheko: II, iSiza iKlasi D |
| I-SS = 1.28 g, i-S1 = 0.43 g, i-SMS = 1.54 g, i-SM1 = 1.09 g, i-SDS = 1.03 g, i-SD1 = 0.73 g |
| Ukusebenza okuqhelekileyo (isigaba ukuya kwisigaba) | 34.5kV |
| Ukusebenza okuphezulu (isigaba ukuya kwisigaba) | 38kV |
| Uqwalaselo lokujika | I-Delta |
| Uvavanyo lweBushing | 600A |
| Ubushushu obujikelezayo | I-200kV BIL |
| Ukufakwa kwe-bushing | I-200kV BIL |
| Ubungakanani be-Bushing | Isithandathu (I-Loop Feed) |
| Ukumelana nesekethe emfutshane | 30kA |
| Nqamla unxibelelwano | Utshintsho lwe-LBOR |
| Nqamula ubungakanani bokutshintsha | Isigaba esinye (1) esi-3 |
| Ukusebenza okuqhelekileyo (isigaba ukuya kwisigaba) | 480V |
| Uqwalaselo lokujika | I-Wye esezantsi |
| Ukufakwa kwe-BIL kwi-winding nakwi-bushing | Imoto ye-30KV |
| Ukumelana nokujikeleza okufutshane | 65 kA* |
| Ubungakanani bomngxuma we-LV bushing spade hole | (8) AKUKHO mngxuma mibini |
| Into eqhelekileyo yokugqithisa umbane | 110% |
| Ukuxhathisa okusekelwe kwisiseko | Hayi |
| Ibhasi yendlela | Ewe |
| Umbane wokubonelela ngesekethe yokulawula | I-AC engama-277V |
| Inkcazo ye-circuit breaker | Uluhlu lwe-UL |
| Ifanelekile ukungena kwinkonzo | Ewe |
| Ubungakanani (ngaphakathi) | I-W*D*H: 83.9*94.7*95.3 |
| Itanki kunye nezixhobo | 4,630lbs |
| Ioyile yomthamo | Iigal ezingama-900 |
| Ubunzima obupheleleyo | 21,600lbs |
Iimpawu eziphambili kunye neenzuzo
Ukusasazwa koMbane okuSebenzayo koGcino lwaMandla
Iitransformer ze-2000kVA zenzelwe ukwehla ukusuka kwiMedium Voltage (MV) ukuya kwiLow Voltage (LV), nto leyo ezenza zilungele ukudityaniswa neeswitchboards kwiinkqubo zokugcina amandla. Olu lungiselelo lokwehla lubalulekile ekuqinisekiseni ukusasazwa kwamandla okugudileyo nokuthembekileyo kwizixhobo ezincedisayo, ukuxhasa ukusebenza kakuhle kweziseko zophuhliso zeBESS.
Ukupholisa Okuzinzileyo Nokusebenza Ngeendleko Eziphantsi
Ngokuhambelana nokuzibophelela kwe-JZP Transformer ekuzinzeni, abaguquli basebenzisa ioyile ebolayo njengolwelo olupholisa. Esi sisombululo sinobuhlobo nokusingqongileyo asiboneleli nje kuphela ngeempawu zokukhusela eziphezulu kodwa sikwaxhasa ukonga amandla.
Ukuqina kunye noKhuseleko okwakhelwe ngaphakathi
IiNqanawa ze-NEMA 3R: Iitransformer zethu zigcinwe kwiindawo zombane ezilinganiswe yi-NEMA 3R ezingangeni mvula, zingangeni qhwa, kwaye zingangeni khephu, ezinezixhobo zokukhupha amanzi ezakhelwe ngaphakathi. Ezi ndawo zombane zibonelela ngokhuseleko oluqinileyo kwiimeko zezulu, zikhusela izixhobo zombane zangaphakathi kwaye ziqinisekisa ukuqina kwexesha elide nokuba kwiimeko ezinzima zendalo.
Iimpawu zokungaPhazamisi kunye noKhuseleko: Zenzelwe ukhuseleko engqondweni, ii-transformer zineendlela ezahlukeneyo zokutshixa nokubopha ukuthintela ukufikelela nokuphazamiswa okungagunyaziswanga, ukunciphisa umngcipheko wokwebiwa kunye nokuqinisekisa ukusebenza ngokukhuselekileyo ngamaxesha onke.
Uyilo Olusebenziseka Kakuhle Lokhuseleko Nokusebenza Kakuhle
Icala le-transformer elinombane ophantsi linoyilo olukhethekileyo olufakwe ecaleni olunomqala ukuze kube lula ukuqhagamshela kwi-switchboard. Iigeyiji ezifakwe ngaphandle, iivalvu zesampulu, kunye neenkqubo zokukhupha amanzi zigcinwe kwikhabhathi etshixwayo enesitshixo sebholiti esinamanqaku amahlanu. Olu yilo lukhethekileyo luvumela abaqhubi ukuba bahlole ngokukhuselekileyo amanqanaba eoyile, bavavanye iigeyiji, kwaye benze imisebenzi yokulungisa ngaphandle kokuzibeka kwi-bushings ye-high-voltage (HV) okanye ye-low-voltage (LV), nto leyo ephucula kakhulu ukhuseleko kunye nokusebenza kakuhle.

Iigeyiji zangaphandle zetransformer ezifakwe kwiPad
Ukubeka esweni okuPhambili kunye nezilumkiso ezikude
Ukuqinisekisa ukusebenza okuqhubekekayo nokufanelekileyo, i-transformer ixhotyiswe ngezikhombisi zenqanaba leoyile kunye nobushushu ezibonisa iindawo ezimbini zokunxibelelana ukuze zijongwe kude. Ezi zikhombisi zibonelela ngedatha yexesha langempela kubaqhubi, zithumela imiqondiso ye-alamu xa inqanaba leoyile liphezulu kakhulu okanye liphantsi kakhulu. Ukongeza, ukuba ubushushu bolwelo olupholileyo ludlula i-85°C, inkqubo iya kubangela i-alamu. Ukuba ubushushu bunyuka ngaphezu kwe-105°C, i-transformer iya kuqhawula ngokuzenzekelayo kwigridi ukuthintela ukugqithisa kakhulu kunye nomonakalo onokubakho, ukuqinisekisa ukhuseleko kunye nokuthembeka kwenkqubo.

Umgangatho kunye nokuthobela imithetho
Ii-JZP Transformers zenziwe ngokuhambelana ngokungqongqo nemigangatho ephambili kushishino, kuquka i-UL, i-ANSI, i-IEEE, kunye ne-NEMA, ziqinisekisa ukusebenza okuphezulu, ukuthembeka, kunye nokhuseleko. Ukuzibophelela kwethu kumgangatho kunye nokuvelisa izinto ezintsha kuqinisekisa ukuba i-transformer nganye yakhiwe ngokweemfuno eziphezulu, inikezela ngenkonzo ethembekileyo kulo lonke ixesha lokusetyenziswa kwezixhobo.

Buza Ngoku!
Ukuba unemibuzo malunga neemveliso zethu okanye uluhlu lwamaxabiso, nceda usishiyele i-imeyile yakho kwaye siya kuqhagamshelana nathi kwiiyure ezingama-24.