+86 18068001229 01
Isiguquli Esifakelwe I-Single Phase Pole—50kVA
Ingcaciso yeMveliso
I-transformer ye-JZP Transformer engama-50 kVA ene-pole yesigaba esinye, iqinisekisiwe ukuba ine-UL listing kwaye ixhaswa yingxelo yokuhlolwa kwe-CESI. Ngoluhlu olubanzi lwe-voltage oluyi-2.4-34.5kV, i-transformer inamathela kwimigangatho eyahlukeneyo yamazwe ngamazwe efana ne-ANSI, i-IEEE, i-CSA, i-IEC, kunye ne-DOE, iqinisekisa ukuhambelana nokusebenza kwehlabathi. Isebenzisa ubuchule beminyaka engama-20 kuyilo kunye nokuthumela ngaphandle, iqela le-JZP Transformer lixhotyiswe ukujongana neemfuno ezahlukeneyo, linikezela ngezisombululo ezinokwenziwa ngokwezifiso kwii-transformers ezikhethekileyo. Ngokuzibophelela okukhulu ekwanelisekeni kwabathengi kunye nomgangatho, i-JZP Transformer inikezela ngeemveliso ezithembekileyo, ezisebenzayo, nezikhuselekileyo ukuhlangabezana neemfuno ezizodwa zabathengi kwihlabathi liphela.

Isiguquli esifakwe kwiNgxobo ye-13.8 kV 50 kVA
I-D-50-13.8/0.12-0.24kV, i-transformer ene-50 kVA exhonywe kwiipali, yenziwe ngobuchule yi-JZP Transformer, ihambelana nemigangatho ye-IEEE C57.12.20. Ngomthamo we-50kVA, isebenza kwi-13.8 kV kwicala eliphambili kwaye inika i-120/240V kwicala lesibini. I-transformer inee-bushings ezimbini ze-voltage ephezulu, ii-bushings ezintathu ze-voltage ephantsi, kunye nee-arresters ezimbini zokuphucula ukusebenza kunye nokhuseleko.
I-JZP Transformer iqinisekisa umgangatho ophezulu kunye nokuthembeka kuyo yonke iyunithi. Ii-transformer zenzelwe ukuhlangabezana neemfuno ezizodwa zenethiwekhi yokusasazwa kwamandla yaseGuyana, ukuqinisekisa ukunikezelwa kombane okusebenzayo nokungaguquguqukiyo. Ngokuzibophelela okukhulu ekwanelisekeni kwabathengi, i-JZP Transformer inikezela ngeemveliso ezigqwesileyo kunye nenkonzo egqwesileyo ukuhlangabezana neemfuno zenkampani eGuyana.

I-14.4 kV 50 kVA Isiguquli seSigaba esinye
I-D-50-14.4/0.12-0.24 yitransformer ene-pole yesigaba esinye engama-50 kVA. Isebenza kwi-24940/14400V (i-voltage ephezulu) kunye ne-120/240V (i-voltage ephantsi) ene-HV bushing enye. Itransformer ine-aluminium winding edibana nemigangatho yokusebenza kakuhle ye-CSA C2.1 kunye ne-CSA 802.1. Isebenza kwi-60Hz kwaye yeyokupholisa ye-ONAN. Itransformer yiClass A insulation.

Isiguquli seSigaba esinye se-16/27.6kV 50 kVA
I-D-50-16-27.6kV/347(600Y)V yitransformer eyahlukileyo ye-50 kVA enesigaba esinye, eyenzelwe ngokukodwa usetyenziso olukhethekileyo. Isebenza kumanqanaba aphezulu ombane we-16kV kunye ne-27.6kV, inika umbane ophantsi kwi-347(600Y)V.
Yenzelwe kwaye yenziwa yiJZP Transformer, ithobela imigangatho engqongqo yeCSA C802.1 kunye neCSA C2.1, iqinisekisa ukusebenza kakuhle kunye nokhuseleko. Le transformer ineendlela ezimbini zokusebenzisa amandla aphezulu: i-16,000V kunye ne-27,600V, nto leyo eyenza ukuba ibe nokuguquguquka kwiimeko ezahlukeneyo zokusasazwa kwamandla. Ine-bushing ye-voltage ephezulu, ii-bushing ezimbini ze-voltage ephantsi, kunye ne-Dual voltage switch ukuze kube lula ukukhetha amandla.
Izakhono ezikhethekileyo zale transformer yesigaba esinye ye-50kVA yombane ophindwe kabini zibonelela ngeemfuno zombane ezikhethekileyo kulo mmandla, ziqinisekisa ukunikezelwa kombane okuthembekileyo kwaye zihlangabezana nemigangatho ephezulu yoshishino.

Isiguquli seSigaba esinye se-2.4kV 50 kVA
I-D-50-2.4kV/120(240)V yitransformer efakwe kwi-pole engama-50 kVA, ene-single phase, ene-voltage ephezulu ye-2.4 kV kunye ne-voltage ephantsi ye-120V, eyenzelwe ngokukodwa umthengi waseKhanada. Itransformer nganye ixhotyiswe nge-bushing enye ye-high-voltage kunye ne-bushings ezintathu ze-low-voltage, nto leyo eyenza uqhagamshelo lube ngcono. Ezi transformers ziyilwe kwaye zenziwe ngononophelo, zihlangabezana nemigangatho ye-CSA engqongqo, ziqinisekisa ukusebenza okugqwesileyo kunye nokhuseleko. Ngokuzibophelela okungagungqiyo ekugqweseni, ezi transformers zenzelwe ukwanelisa iimfuno ezithile zomthengi waseKhanada, zibonelela ngosasazo lwamandla oluthembekileyo kwaye zithobela yonke imigaqo efunekayo yoshishino.

Buza Ngoku!
Ukuba unemibuzo malunga neemveliso zethu okanye uluhlu lwamaxabiso, nceda usishiyele i-imeyile yakho kwaye siya kuqhagamshelana nathi kwiiyure ezingama-24.









