IiTransformers eziPhakathi kwePad eziSebenzayo zangaphandle zeSigaba esinye

I-transformer ene-pad enesigaba esinye sisixhobo sokusasaza umbane esisezantsi esenzelwe ukunciphisa amandla e-voltage ephakathi ukuya kumanqanaba aphantsi asebenzisekayo kwiindawo zokuhlala, zorhwebo, kunye nezicelo zemizi-mveliso ezilula. Zigqunywe kwindawo eqinileyo, enganyangekiyo, ezi transformers zisetyenziswa kakhulu kwiindawo zasezidolophini, ezisemaphandleni, nakwiindawo zasezidolophini apho ubuhle, ukhuseleko, kunye nokulungiswa kwendawo zizinto eziphambili.

    Ezona mpawu

    Uyilo oluNcinci nolukhuselekileyo: Ezi yunithi zigcinwe kwiindawo ezivalekileyo ezingatshixwayo (ezihlala zisetyenziswa njengentsimbi okanye i-aluminium engamelani nokugqwala), zikhusela izinto zangaphakathi ekonakalisweni, kwimozulu, nasekudibaneni ngengozi.
    Ukusebenza kakuhle okuphezulu: Isebenzisa izixhobo eziphambili zeprimiyamu (umz., intsimbi engaguqukiyo okanye isinyithi sesilicon esijolise kwiingqolowa) kunye nee-windings ezenziwe ngobuchule obuchanekileyo ukunciphisa ilahleko yamandla, ihlangabezana nemigangatho yokusebenza kakuhle ye-DOE 2016 kunye ne-IEC 60076.
    Ukusebenza kwengxolo ephantsi: Yenziwe ngezinto zokunciphisa ingxolo kunye neesekethe zemagnethi ezilungiselelwe kakuhle, zilungele iindawo ezinovakalelo lwengxolo ezifana neendawo zasekuhlaleni kunye nezibhedlele.
    Ulondolozo oluphantsi: Ulwakhiwo oluvaliweyo (oluzaliswe yioyile okanye olomileyo) luthintela ungcoliseko, ngelixa iinkqubo zokubeka esweni eziphambili zivumela ukugcinwa kwangaphambili.
    Ukuthobela uKhuseleko: Ineendawo ezivalekileyo ezisekelwe phantsi komhlaba, izikhombisi-ndlela zokulungisa iimpazamo, izixhobo zokunciphisa uxinzelelo, kunye noyilo olumelana nee-arc. Iimodeli ezizaliswe yioyile zisebenzisa ulwelo olumelana nomlilo okanye olubolayo.
    I-Transformer efakwe kwi-Cooper Oil eQokelelweyo i-High Frequency 10001I-Transformer Efakwe kwi-Cooper Oil eQokelelweyo i-High Frequency 10002I-Transformer efakwe kwi-Cooper Oil eQokelelweyo i-High Frequency 10003
    Izisombululo zeTransformer eziNxibelelekileyo zeSigaba esinye
    • Izisombululo zeTransformer eziNxibelelekileyo zeSigaba esinye (1)
    • Izisombululo zeTransformer eziNxibelelekileyo eziPhase-eSinye (2)
    • Izisombululo zeTransformer eziNxibelelekileyo eziPhase-eSinye (3)
    • Izisombululo zeTransformer eziNxibelelekileyo eziPhase-eSinye (4)
    • Izisombululo zeTransformer eziNxibelelekileyo eziPhase-eSinye (5)
    • Izisombululo zeTransformer eziNxibelelekileyo eziPhase-eSinye (6)
    I-Transformer Efakwe kwi-Cooper Oil01

    Iinkcukacha zobugcisa

    Uvavanyo lweVoltage: I-voltage yokuqala isusela kwi-2.4 kV ukuya kwi-34.5 kV, kunye neziphumo zesibini ze-120/240V okanye i-230/400V (isigaba esinye).
    Ubungakanani: Ifumaneka ukusuka kwi-25 kVA ukuya kwi-500 kVA, ixhasa iimfuno ezahlukeneyo zomthwalo, kuquka iindawo zokuhlala ezidibeneyo kunye nezakhiwo ezincinci zorhwebo.
    Ukupholisa: Iimeko ezifakwe kwi-oyile (ONAN) okanye uhlobo olomileyo (olungena umoya okanye olufakwe kwiikhaphu), kunye nemida yokunyuka kwamaqondo obushushu ngokwe-IEEE C57.12.25.
    Uvavanyo loKhuseleko: Ii-enclosures ezilinganiswe nge-IP55 nangaphezulu ngenxa yokumelana nothuli namanzi.

    Izicelo

    Ukusasazwa kweMimandla yasezidolophini: Ilungele uthungelwano lwamandla angaphantsi komhlaba kwizixeko, kwiindawo ezikufutshane, nakwiindawo ezicwangcisiweyo.
    Iindawo zorhwebo: Inika amandla iindawo zokuthenga, iipaki zeeofisi, kunye nophuhliso olusetyenziselwa izinto ezahlukeneyo olunempembelelo encinci ebonakalayo.
    Iinkqubo zamandla ahlaziyekayo: Idibana nokufakelwa kwamandla elanga/omoya okanye iigridi ezincinci ukuze kusasazwe amandla asekuhlaleni.
    Iziseko Zophuhliso Ezibalulekileyo: Ixhasa izibhedlele, izikolo, kunye namaziko edatha afuna amandla athembekileyo, angxolo iphantsi.

    Iingenelo ngaphezu kwezinye iindlela

    Ukusebenza kakuhle kwesithuba: Isusa isidingo seepali, ikhulula indawo esemoyeni kwaye inciphisa ukuxinana kwamehlo.
    Ukhuseleko oluphuculweyo: Iindonga ezisezantsi komhlaba zithintela ukufikelela koluntu, nto leyo enciphisa iingozi zokutshayiswa ngumbane.
    Ukukhula: Uyilo lweemodyuli luvumela ukuphuculwa komthamo okulula ukuze kuhambelane neemfuno zamandla ezikhulayo.
    Ukuqina: Izinto ezimelana nokugqwala kunye nolwakhiwo oluqinileyo ziqinisekisa ukuba zihlala ixesha elide kwiindawo ezinzima.

    Ukufakwa kunye nokugcinwa

    Mnaukufakelwa: Ifakwe kwiipadi zekhonkrithi ezinomoya ofanelekileyo kunye nokukhupha amanzi. Ifuna ukulungiswa okuncinci kwendawo xa ithelekiswa nee-vaults ezingaphantsi komhlaba.
    Ukufikeleleka: Uyilo lokufikelela ngaphambili lwenza kube lula ukugcinwa, ukuhlolwa, kunye nokulungiswa ngaphandle kokuyichitha iyunithi.
    Ukubeka iliso: Iimodeli eziphambili ziquka izinzwa ezisebenza nge-IoT zokulandelela umthwalo ngexesha langempela, umgangatho weoyile (ukuba ikhona), kunye nobushushu.
    Umsebenzi wobomi: Yenzelwe iminyaka engama-30-40 yenkonzo ngokuhlolwa rhoqo (umz., uvavanyo lweoyile, ukuvavanywa kwe-bushing, kunye nemifanekiso yobushushu).

    Ukuthobela imithetho kunye nozinzo

    Ihambelana nemigangatho ye-IEEE C57.12.25, i-IEC 60076, kunye ne-NEMA ST-20.
    Iinketho ezinobuhlobo nokusingqongileyo ziquka ii-transformers zohlobo olomileyo (ezingenawo ioyile), izinto ezisetyenziswa kwakhona zokuvala, kunye nolwelo olugcina ubushushu olubolayo.
    I-transformer ene-pad enesigaba esinye sisisombululo esiguquguqukayo, esikhuselekileyo, nesisebenzayo kwiinethiwekhi zanamhlanje zokusasaza umbane. Ukufakelwa kwayo kwinqanaba lomhlaba, kunye nokhuseleko oluqinileyo kunye nempembelelo ephantsi kwindalo esingqongileyo, kuyenza ibe yinto ebalulekileyo kwiinkonzo zasekhaya nakubaphuhlisi ababeka phambili ukhuseleko, ubuhle, kunye nokuthembeka kokusebenza. Nokuba inika amandla iindawo zasezidolophini okanye iindawo zamandla ahlaziyekayo, le transformer ilinganisela ukusebenza kunye nokuzinza.
    I-Transformer Efakwe kwi-Oyile yeCooper02I-Transformer Efakwe kwi-Oyile yeCooper03I-Transformer efakwe kwi-oyile yeCooper04I-Transformer Efakwe kwi-Oyile yeCooper05

    Iingenelo zemveliso

    1. Izixhobo ezingundoqo kunye noyilo lokujika
    Izinto ezingundoqo​
    IiCores zeAmorphous Alloy: Sebenzisa ii-alloys zesinyithi ezingaphantsi kwelahleko, ezibonelela ngokulahleka kwesinyithi okuphantsi kwama-70–80% xa kuthelekiswa nentsimbi ye-silicon yendabuko. Ukungena kwazo okuphezulu kunye nokunciphisa amandla emagneto kunciphisa ingxolo kunye nokungcangcazela, okulungele iindawo zokuhlala.
    I-Silicon Steel eHleliweyo: I-silicon steel ephucukileyo eqengqelekayo ebandayo ene-laminations ezisikiweyo nge-laser inciphisa izithuba zomoya kunye nokulahleka kombane we-eddy, iphucula ukusebenza kakuhle (ukuya kuthi ga kwi-98%) kunye nokuzinza kobushushu.
    Uyilo lweWindling​
    Iifestile zeFoyile: Iifestile zefoyile yeCopper okanye yealuminium zinciphisa ukuvuza kwamanzi kunye namandla okujikeleza okufutshane, ziphucula ukuqina kokugqithisa.
    I-Layered Litz Wire: Ii-multi-strand wire windings ze-Litz zinciphisa ulusu kunye nemiphumo yokusondela, ziphucula ukusasazwa kwangoku kunye nokusebenza kakuhle.
    Ulungelelwaniso lweCompact Coil: Iindlela zokucinezela i-Axial kunye ne-resin-impregnation zonyusa amandla oomatshini kunye nokuqhuba kobushushu.

    2. Iinkqubo zokuvala ubushushu
    I-Epoxy Resin Casting: Ii-transformer zohlobo olomileyo zisebenzisa i-vacuum-pressure impregnation (VPI) ene-epoxy resin yobushushu obuphezulu (i-Class H insulation), ebonelela ngokumelana nomlilo okuqinisekisiweyo yi-UL kunye nokumelana nokufuma.
    Ukufakwa kobushushu obufakwe kwi-oyile: Kwiiyunithi ezinomthamo ophezulu, ii-oyile zokufaka ubushushu eziphezulu (umz., ulwelo olusekwe kwi-ester) ezidityaniswe nephepha leNomex zibonelela ngokhuseleko lomlilo kunye namandla e-dielectric ukuya kuthi ga kwi-200 kV.
    Ukufakwa kobushushu okuphuculweyo kweNano: Ii-epoxy composites ezizaliswe yi-silica ziphucula ukumelana nokukhutshwa okungaphelelanga, zandisa ubomi benkonzo kwiindawo ezifumileyo okanye ezingcolisiweyo.

    3. Ulawulo lobushushu​
    Ukupholisa Umoya Ngokwendalo Ngeoyile: Ukujikeleza kweoyile kunye neeradiator ezifakwe amachaphaza zibonelela ngokupholisa okungasebenziyo ukuze kuqhubeke ukusebenza ngomthwalo ophezulu.
    Ukupholisa Umoya Onyanzelekileyo: Iifeni ezilawulwa bubushushu ziyasebenza xa amaqondo obushushu eoyile edlula imida, nto leyo egcina imida yokusebenza ikhuselekile.
    Ii-Smart Thermal Sensors: Ii-thermistors ezifakiweyo kunye neenkqubo zokubeka esweni ezisebenzisa i-IoT zivuselela ii-alamu okanye iiprotokholi zokucinywa komthwalo ukuthintela ukugqithisa kakhulu.

    4. Uyilo kunye noKhuselo lweZakhiwo​
    Uyilo lweModular kunye neCompact
    I-Enclosure Efakwe Ezantsi: Ii-concrete okanye ii-polymer pads eziqinileyo ziqinisekisa uzinzo kunye nokumelana nokubiwa.
    Ukuvalwa Okulinganiselwe yi-IP68: Izivalo ezivalekileyo ezinee-gasket ze-EPDM zikhusela emanzini, uthuli, kunye nokungena kweempuku, nakwiindawo ezisengozini yezikhukula.
    Iingubo Ezingagqwaliyo: Iingubo zentsimbi ezigqunyiweyo okanye ze-aluminium ezishushu ezineengubo ze-polyurethane powder ezimelana nokubola kwe-UV kunye nokutshizwa ngetyuwa.
    Iimpawu zoKhuseleko
    Ukhuseleko Lokugquma Kwangaphakathi: Izithinteli zokugquma kwe-zinc oxide (MOA) kunye nee-surge capacitors zithintela ii-transients ezibangelwa ngumbane.
    IiValvu Zokunciphisa Uxinzelelo: Zikhupha iigesi ngokuzenzekelayo xa kukho iziphene zangaphakathi, zithintela ukungaphumeleli kokuqhuma.
    Uyilo Olungaphazamisiyo: Iiphaneli zokufikelela ezitshixwayo kunye neethegi zokuthintela ubusela ezisebenza ngeGPS zithintela ukonakala.

    5. Imisebenzi Ephambili
    Iinkqubo zokujonga imeko: Izinzwa ezakhelwe ngaphakathi zilandelela ubushushu beoyile, amanqanaba omthwalo, kunye nokukhutshwa okungaphelelanga, zithumela idatha kwiinkqubo ze-SCADA ukuze zigcinwe kwangaphambili.
    Ukuphucula Ukusebenza Kombane: Ii-algorithms eziqhutywa yi-AI zihlengahlengisa ngokuguquguqukayo ii-tap changer ukunciphisa ilahleko phantsi kweemeko ezahlukeneyo zomthwalo.
    Uyilo Olunobuhlobo Nokusingqongileyo: Iioyile zokukhusela ezisekelwe kwibhayoloji kunye nezixhobo zepolymer ezinokuphinda zisetyenziswe zihambelana neenjongo zozinzo.

    Izicelo eziphambili kunye neendlela zexesha elizayo​
    Ilungele izitishi zedolophu, ukuhlanganiswa kwamandla avuselelekayo (umz., iifama zelanga), kunye neepaki zoshishino.
    Uphuhliso lwexesha elizayo luquka ii-solid-state transformers (ii-SST) zokuguquguquka kwegridi kunye nezixhobo zokugquma eziziphilisayo ukuze kuncitshiswe ixesha lokungasebenzi.

    Isishwankathelo​
    IiTransformers ezifakwe kwiSigaba esinye zigqwesile ngokusebenzisa ii-cores ezingaphantsi kwelahleko, ulawulo olukrelekrele lobushushu, uyilo lweemodyuli, kunye neenkqubo zokukhusela ezineeleya ezininzi. Ukudibana kwazo kokusebenza kakuhle, ukhuseleko, kunye nokuzivumelanisa nezimo kuzenza zibe lilitye lesiseko lothungelwano lwanamhlanje lokusasaza, kunye notshintsho oluqhubekayo oluqhuba iigridi eziluhlaza nezikrelekrele.
    I-Transformer Efakwe kwi-Oyile yeCooper06I-Transformer Efakwe kwi-Cooper Oil07I-Transformer Efakwe kwi-Oyile yeCooper08I-Transformer Efakwe kwi-Oyile yeCooper09

    Buza Ngoku!

    Ukuba unemibuzo malunga neemveliso zethu okanye uluhlu lwamaxabiso, nceda usishiyele i-imeyile yakho kwaye siya kuqhagamshelana nathi kwiiyure ezingama-24.

    Leave Your Message