2025-07-19

Ngowama-2024, sahambisa i-transformer ye-12 MVA ePhilippines. Le transformer inamandla alinganisiweyo e-12,000 KVA kwaye isebenza njenge-transformer esezantsi, iguqula i-voltage yokuqala ye-66 KV ibe yi-voltage yesibini ye-33 KV. Sisebenzisa i-copper kwizinto ezijikelezayo ngenxa yokuqhuba kwayo umbane okuphezulu, ukusebenza kakuhle kobushushu, kunye nokumelana nokugqwala.
Yenziwe ngobuchwepheshe obuphezulu kunye nezixhobo ezikumgangatho ophezulu, i-12 MVA power transformer yethu inika ukuthembeka nokuqina okugqwesileyo.
Apha e-JZP, siqinisekisa ukuba yonke i-transformer esiyihambisayo ivavanywa ngokupheleleyo. Siyazingca ngokuba sigcine irekhodi elingenasiphako elingenasiphako kangangeminyaka engaphezu kweshumi. Iitransformer zamandla zenzelwe ukuhlangabezana nemigangatho engqongqo ye-IEC, i-ANSI, kunye nezinye iinkcukacha eziphambili zamazwe ngamazwe.
 
Ububanzi bobonelelo
Imveliso: Isiguquli samandla esifakwe kwioyile
Amandla Alinganisiweyo: Ukuya kuthi ga kwi-500 MVA
I-Voltage Eyintloko: Ukuya kuthi ga kwi-345 KV
 
Iinkcukacha zoBugcisa
Iinkcukacha ze-12 MVA power transformer kunye nephepha ledatha

Imodeli SFZ11-12 MVA-66/33KV
Uhlobo Isiguquli samandla esintywilisiweyo esingu-0il
Umgangatho IEC60076
Amandla Alinganisiweyo 12000 KVA
Izihlandlo 60HZ
Isigaba 3
Uhlobo Lokupholisa AKUKHO NGOKOMTHETHO
I-Voltage ePhambili 66 KV
I-Voltage yesibini 33 KV
Izinto zokuhombisa Ithusi
Iqela leVector Unyaka woku-1
Ukunganyamezelani 10%
Thepha iTshintsho I-OLTC
Uluhlu lokuThepha ±8*1.25%
Izixhobo Umgangatho
Amagqabaza N / A

Indlela yokupholisa ye Isiguquli esintywiliselwa kwioyile Ngokwesiqhelo ibandakanya ukusebenzisa ioyile yetransformer njengesixhobo sokupholisa esiphambili. Le oyile ineenjongo ezimbini eziphambili: isebenza njengesigqubuthelo sombane kwaye inceda ekukhupheni ubushushu obuveliswa ngaphakathi kwitransformer. Nazi ezinye iindlela eziqhelekileyo zokupholisa ezisetyenziswa kwiitransformer ezintywilisiweyo kwioyile:
1. Ioyile yoMoya weNdalo weNdalo (i-ONAN)
● Inkcazo:
Kule ndlela, i-convection yendalo isetyenziselwa ukujikeleza ioyile ngaphakathi kwitanki ye-transformer.
o Ubushushu obuveliswa zii-windings ze-transformer bufunxwa yioyile, ethi emva koko inyuke ize idlulisele ubushushu kwiindonga zetanki.
Ubushushu buyasuswa bungene emoyeni ojikelezileyo nge-convection yendalo.

● Usetyenziso:
o Ifanelekile kwiitransformer ezincinci apho ubushushu obuveliswayo bungagqithisi.

● Inkcazo:
Le ndlela ifana ne-ONAN, kodwa ibandakanya ukujikeleza komoya okunyanzelekileyo.
o Iifeni zisetyenziselwa ukuvuthela umoya phezu kwemiphezulu yeradiator yetransformer, nto leyo ephucula inkqubo yokupholisa.

● Usetyenziso:
o Isetyenziswa kwiitransformer eziphakathi apho kufuneka ukupholisa okongeziweyo ngaphaya komoya wendalo.

● Inkcazo:
Kwi-OFAF, zombini ioyile nomoya zijikeleziswa kusetyenziswa iimpompo kunye neefeni, ngokwahlukeneyo.
o Iimpompo zeoyile zijikeleza ioyile ngetransformer nakwiiradiyetha, ngelixa iifeni zinyanzela umoya kwiiradiyetha.

● Usetyenziso:
o Ifanelekile kwiitransformer ezinkulu apho i-convection yendalo inganelanga ukupholisa.

● Inkcazo:
Le ndlela isebenzisa amanzi njengesixhobo sokupholisa esongezelelweyo.
o Ioyile ijikeleziswa ngee-heat exchangers apho amanzi apholisa ioyile.
Emva koko amanzi ayapholiswa ngenkqubo eyahlukileyo.

● Usetyenziso:
Isetyenziswa kwiitransformer ezinkulu kakhulu okanye kwiindawo zokufakelwa apho indawo yokupholisa umoya incinci kwaye kufuneka ukusebenza kakuhle okuphezulu.

● Inkcazo:
o Ifana ne-OFAF, kodwa inendawo ehamba ngayo ioyile ethe ngqo.
o Ioyile iqondiswa ngemijelo ethile okanye imibhobho ukuphucula ukusebenza kakuhle kokupholisa kwiindawo ezithile ezishushu ngaphakathi kwi-transformer.

● Usetyenziso:
o Isetyenziswa kwiitransformer apho kufuneka ukupholisa okujoliswe kuko ukulawula ukusasazwa kobushushu okungalinganiyo.

● Inkcazo:
o Le yindlela yokupholisa ephucukileyo apho ioyile iqondiswa ukuba ihambe ngeendlela ezithile ngaphakathi kwi-transformer, ukuqinisekisa ukupholisa okujoliswe kuko.
o Ubushushu budluliselwa emanzini ngokusebenzisa izixhobo zokutshintsha ubushushu, ngokunyanzelwa ukuba bujikeleze ukuze bukhuphe ubushushu ngokufanelekileyo.

● Usetyenziso:
o Ilungele ii-transformers ezinkulu kakhulu okanye ezinamandla aphezulu kwiindawo zoshishino okanye kwiindawo ezisetyenziswa kakhulu apho ulawulo oluchanekileyo lobushushu lubaluleke kakhulu.

2. I-oyile yendalo eqhutywa ngumoya (i-ONAF)
3. Umoya Oqhutywa Ngeoyile (OFAF)
4. Amanzi Aqhutywa Ngeoyile (OFWF)
5. Umoya oqhutywa yi-Oyile (ODAF)
6. Amanzi Aqhutywa Yioyile (ODWF)