+86 18068001229 Ngaphakathi kwe-JZP's Three-Phase Pad-Mounted Transformer: Ukuntywila nzulu kwi-Smart Grid Innovation

Kwimeko eguqukayo yetekhnoloji yegridi ekrelekrele, ii-transformers ze-JZP ezifakelwe ii-pad phase ezintathu (ii-PMT) ziye zavela njengesisombululo esitshintsha umdlalo ukuze kube lula ukusebenza. Ukusasazwa koMbane. Ukudibanisa uyilo oluncinci kunye nobunjineli obuphambili, ezi "ziindawo zamandla ezikrelekrele" zichaza ngokutsha ukuthembeka kunye nokuzinza. Masihlolisise ukwakheka okuntsonkothileyo kwee-PMT ze-JZP size sifumanise imimangaliso yetekhnoloji enika amandla iziseko zophuhliso zanamhlanje.
1. Uyilo lweModular: Iseli yamandla ekrelekrele
IiPMT zeJZP zamkela uyilo oluguqukayo lwe-"SmartCube" oludibanisa iinkqubo ezintathu ezibalulekileyo kwindawo enye, ekwaziyo ukumelana nemozulu:
Igumbi leVoltage ephezulu: Izitshixi zokuvala umthwalo ezivaliweyo nge-vacuum ezine-SF6 gas insulation
I-Transformer Core: I-Advanced amorphous alloy core inciphisa ukulahleka kwamandla
Ukusasazwa kweVoltage ephantsi: Abalawuli belogic abacwangcisiweyo abanonxibelelwano lwe-IoT
Olu yilo lunciphisa ixesha lokufakela ngama-60% xa kuthelekiswa nezikhululo zemveli kwaye luthatha indawo engaphantsi ngama-40%.
2. Inkqubo yeVolthi ephezulu: Ubunjineli boKhuseleko lokuqala
2.1 Inkqubo yoKhuselo lweHybrid
Isithinteli seVacuum: Ilinganiswe nge-63kA short-circuit current ene-10,000 mechanical operations
IiFusi eziBonayo kabini: Ukujonga ubushushu kunye nomlinganiselo wamandla ukuze kukhuselwe ngaphambi kokusetyenziswa
Ukudibanisa oomatshini: Kuthintela umbane ngengozi ngexesha lokulungiswa
2.2 Ii-Smart Bushings
Ii-Polymer Insulators: Zimelana namandla entsimi ye-100kV/m
I-RFID Tagging: Ivumela ukujonga imeko ngendlela engangenisi ntsholongwane
Ukuzicoca: Kunciphisa ukungasebenzi kakuhle kwezinto ngenxa yongcoliseko ngama-75%
3. I-Transformer Core: Ubuchule beMagnetic
3.1 Ubuchwepheshe be-Amorphous Alloy
| Ipharamitha | Iinkcukacha zeJZP | Umgangatho weShishini |
| Ukulahleka Okungundoqo (W/kg) | ≤0.12 @50Hz | 0.35 |
| Uxinano lweMagnetic Flux | 1.45T | 1.5T |
| Inqanaba lengxolo | ≤45dB(A) | ≤55dB(A) |
Uyilo lwe-triple-limb stacked core lunciphisa ilahleko ye-eddy current nge-40% ngeendlela ze-flux ezilungiselelweyo
3.2 I-Active Cooling Matrix
Iileya zeZinto zoTshintsho lweSigaba (PCM): Funxa ubushushu obuyi-300kJ/m³
IiFin ezibangela iVortex: Yonyusa ukujikeleza kwendalo nge-250%
Iindlela zokuPholisa zeHybrid: Ukutshintsha ngokuzenzekelayo phakathi kwe-convection/radiation ngokusekelwe kumthwalo
4. Inkqubo yeVolthi ephantsi: Ubukrelekrele obusebenzisana neGrid
Ukulungiswa kwamandla ashukumisayo
Imbuyekezo ye-VAR ehlengahlengiswayo: Igcina i-PF >0.98 kuzo zonke iimeko zomthwalo
Ukunciphisa iHarmonic: Isihluzi esisebenzayo se-4th-order sirhoxisa ukuya kuthi ga kwi-25th harmonics
Ukuthintela ubumnyama: Ukudluliselwa kwe-UPS ngaphandle komthungo nge-
5. Iphakheji Yokumelana Nokusingqongileyo
5.1 Ukhuseleko Lomgangatho Wezomkhosi
Uvavanyo lwe-IP68/IP69K: Iyasinda ekuntywilisweni emanzini angama-2m kangangemizuzu engama-30
Ukumelana neNkungu yeTyuwa: Iphumelela uvavanyo lwe-ASTM B117 lweeyure ezili-1000
Ukukhusela i-EMI: 5.2 Izinto ezilungele ukusingqongileyo
I-Dielectric Fluid ebolayo: i-ester esekwe kwizityalo eyi-100%
I-Aluminium Enclosure Enokuphinde isetyenziswe: 98% yezinto ezinokuphinda zisetyenziswe
Uyilo lokuvuza kwe-Zero-Oil: Isebenzisa ukugcinwa kwe-nitrogen exinzelelweyo
6. Iimpawu zokudibanisa i-Smart Grid
Ujongano lweDistributed Energy Resource (DER): Ixhasa ukuhlanganiswa kwe-solar PV/Storage
Ukubuyiselwa kweVolthi yeDynamic (DVR): Igcina uzinzo lweVolthi ye-±1%
Isango Lokuphendula Kwimfuno: Ithatha inxaxheba kwiimarike zeenkonzo ezincedisayo
Amabali empumelelo yesicelo
Ii-Urban Microgrids: Ukunika amandla izindlu ezingaphezu kwe-15,000 kwiSixeko esiZinzileyo saseDubai
Izisombululo zeZiko leDatha: Ixesha lokusebenza le-99.999% kwizibonelelo ze-AWS eSingapore
Ukufakelwa kombane kuloliwe: Ukuguqulwa kwe-25kV AC/DC kwiitreni ezihamba ngesantya se-300km/h
Nxibelelana neJZP Namhlanje
Ubunjineli bekamva lakho lamandla ngezisombululo ze-Intelligent Transformer
Inkxaso yoBugcisa: +86 16655239333
Zonke iinkcukacha zobugcisa ziyahambelana nemigangatho ye-IEC 60076-11 kunye ne-UL 1561.
Ukunika amandla igridi yangomso namhlanje – Izisombululo zeJZP Power