Ii-Autoregulators, kuquka ii-autotransformers kunye ne-automatic Umlawuli weVoltages (ii-AVR), zizixhobo ezibalulekileyo zokugcina amanqanaba ombane azinzileyo kwiinkqubo ezahlukeneyo zombane. Nangona amagama anjengelithi "autoregulator" esenokuvakala engaqhelekanga kubantu abangengoochwephesha, ezi zixhobo zijongana nemingeni yehlabathi kulawulo lwamandla. Apha ngezantsi kukho uhlalutyo oluneenkcukacha lwemigaqo yokusebenza kwazo, ulwahlulo, kunye neempawu eziphambili.

1. Imigaqo Yokusebenza

Ii-Autoregulators zisebenza ngokusebenzisauhlengahlengiso lwe-voltage oluqhubekayongokutshintsha iiparameter zokusebenza kwe-transformer.

  • Uyilo oluPhambiliIindidi ezimbini eziphambili zisetyenziswa rhoqo:
  • I-Ring Core: Incinci kwaye isebenza kakuhle, ilungele ukusetyenziswa kwe-voltage ephantsi ukuya kwephakathi.
  • Umongo weKholamu: Ifanelekile kwiinkqubo ezinomthamo ophezulu ngenxa yokuchithwa kobushushu okuphuculweyo.
    • Ulawulo lweVoltage: Ngokulungisa umlinganiselo wokujika kwe-transformer (umz., ukuhambisa ibrashi yekhabhoni ecaleni kwekhoyili), i-voltage yokuphuma iyazinza. Kwi-autotransformers, oku kubandakanya ukusasaza i-voltage kwakhona kwii-windings ezabelwana ngazo.

2. Iindidi eziqhelekileyo

Ii-Autoregulators zahlulwe ngokwendlela eziyilwe ngayo kunye nesicelo:

Uhlobo

Inkcazo

Izicelo

I-Autotransformer

Isiguquli esijijeka ngombane esinye sokuguqula i-voltage ukuya phezulu/ezantsi. Sisebenza kakuhle kwaye singabizi kakhulu.

Oomatshini bemizi-mveliso, iigridi zombane.

Umlawuli weVoltage oZenzekelayo (i-AVR)​

Ilawula i-voltage yokukhupha nge-elektroniki ngokusebenzisa ii-feedback loops. Ibalulekile kwi-electronics ezinobuthathaka.

Iijenereyitha, iinkqubo ze-UPS, amaziko edatha.

Umlawuli weeMoto zeServo

Isebenzisa uhlengahlengiso loomatshini (umz., iiswitshi zempompo) ukulawula i-voltage ngokuchanekileyo. Ifanelekile kwimithwalo eguquguqukayo.

Iilabhoratri, izixhobo zonyango.

3. Iingenelo eziphambili

  • Uyilo oluNcinci: Ii-Autotransformers zifuna indawo engaphantsi ngama-30–50% kunee-transformers eziqhelekileyo ngenxa yokuba zinee-windings ezabelwana ngazo.
  • Ukusebenza kakuhle okuphezulu: Ilahleko ziyancitshiswa (ziphantsi njenge-1–2%) ngokusetyenziswa okuncitshisiweyo kobhedu.
  • Ukuguquguquka: Ixhasa zombini iinkqubo ze-AC kunye ne-DC, kunye neemodeli ezilawula i-voltage ukusuka kwi-160V ukuya kwi-450V.

4. Iindlela zeMarike

  • Icandelo eliPhambili: Abalawuli be-voltage engaguqukiyo bakhokela kwimarike ngenxa yokuthembeka nokuchaneka.
  • Abaqhubi Bokukhula: Ukunyuka kwemfuno yamandla avuselelekayo, iziseko zokutshaja ze-EV, kunye neegridi ezikrelekrele.

5. Izinto eziqwalaselwayo malunga nokuthengwa kwempahla

Xa ukhetha i-autoregulator:

  • Umthamo: Tshatisa isixhobo neemfuno zomthwalo ophezulu (umz., i-20kVA kwiilabhoratri ezincinci, >1MVA kwiifektri).
  • Ukuguquguquka kokusingqongileyoKhetha iimodeli ezilinganiswe nge-IP kwiindawo ezifumileyo okanye ezinothuli.
  • Iziqinisekiso: Qinisekisa ukuthotyelwa kwemigangatho ye-IEC/UL yokhuseleko nokusebenza.